Air conditioners are basically made up of two parts.The condensing unit which is fixed outside ones house and the evaporator coil commonly known as the conditioner coil which is the air handler.The conditioner simply works in a two way form.The evaporator coil picks up the heat and transmits it to the condensing unit outside the house. You may need to repair it after using it for some time. Most firms offering rockford il transmission repair also render its repair.

Air conditions may at times receive various complications which when not taken care of may eventually cause total conditioner failure.Some of this problems are clogs which cause blockage to the filters in the system and prevent their proper functioning, temperature falls during a heat spell and the thermostat may fail to work.Observation is a key factor before proceeding to fix the conditioner.

The power network is first turned off to prevent shocks that may easily occur.Vents in the house must be open to fortify hot and cold air from the heating systems flows in the house.Before starting repairs make sure the exact problem is found to avoid repairing the wrong parts.In the process the furnace filter must be working then afterwards proceed to clean the condenser coils.

One should have the following tools and materials to make work easier. The tools include an adjustable wrench, drill, ratchet set, voltage tester, insulated screw drivers, but driver and a multi meter. The materials include several fuses, condenser fan motor, capacitor, contractor and compressed air.The above are easily purchased online or in any appliance store.

The electrical box that is next to compress compression unit is opened and the discontent is pulled straight out which causes the power shutdown. Afterwards the condenser coils are cleaned. Clogs that had caused blockage of system is removed and new filter replaced in case the previous ones were damaged.

The discontent block contains fuses which are then examined for any scratches by use of a multi meter that is set to its lowest ohms for accurate results. The opposite ends of the fuse are left to come into come intact with the red and black leads. New fuses are replaced in case of any blown ones in the condensing unit but in other cases even after replacement the fuses may still blow up which requires an expert for advice.

Capacitors tend to breakdown too which requires a swap with new capacitors.One might not be really sure of which wires should ho where hence it is advisable to take at least take a photo before replacement to prevent any form of short circuit. A nose pliers is used to pluck each wire and switch the wires to its rightful terminals.

conditioners contractors wearing out is one major problems causing conditioners breakdown.Replace the contractor before removing the wires.Move the wires to the new unit carefully to avoid any mistake.Tighten the connectors where needed then secure the new contractor in the condensing unit.In case of any difficulties contact a profession.




About the Author: